Mikron Stinger 2 Manual de Instruções Página 3

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 18
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 2
3
position of the coil to be parallel to the ground surface. Don't over-tighten the plastic bolt and nut
to not damage the threading of the bolt! The coil cable is wind up tightly around the bearing rod
and is switched to the terminal of the monitor unit. Upon switching of the cable of the coil to the
monitor unit, tighten the well the metal nut of the coupling to the terminal of the box. Upon
switching off, unscrew the nut completely and pull out the coupling without pulling or twisting
the cable of the coil. This way, you will prevent the cable and the conductors in it from
breakdown or short circuit. Finally adjust search coil angle to your preference and
you are ready.
NOTE: Do not allow the cable to flop loosely over the search coil. Since the detector is
sensitive enough to „see― the tiny wires in the cable, a floppy cable can cause false signals
as the search coil senses the moving wires.
The searching frame (coil) is approached to the surface of earth by paying attention to
avoid presence of metals within its range. The cable is sub - connected to the device.
Upon switching of the cable of the searching frame to the monitor unit, tighten the well the metal
nut of the coupling to the terminal of the box. Upon switching off, unscrew the nut completely
and pull out the coupling without pulling or twisting the cable of the coil. This way, you will
prevent the cable and the conductors in it from breakdown or short circuit.
When use the search frames 1x1m. or 2x2m.: The search frame should be held approximately 4 to
6 inch (10 to 15cm.) to ground surface while searching. Do not allow one end of the frame to be
higher than the other. Make sure that no large metal objects are close to the search frame for
initial adjustment. Also, check your shoes or boots since most of them contain metal parts and
you would receive a signal response any time you step near to the coil.
In order to avoid interference of the metal parts of the electronic unit, be sure to carry the
STINGER 2 on the side of your body that is away from the search frame.
The device is switched on through pressing of „ON OFF / CLEAR“ and you see on
the display: Start Detector, the serial number of the device and the software version. Starts
balancing to the ground conditions during which time the display shows
"CLEAR" and you can hear a single sound. This lasts for 3 4 sec., then it is
followed by a double short sound and the device is turned on in general mode
of "VCO" or last used mode. If you wish to work in a mode of discrimination
Vista de página 2