1
STINGER 2
User’s Operating Manual
______________________________________________________________________
Made in Bulgaria
Vista de página 0
1 2 3 4 5 6 ... 17 18

Resumo do Conteúdo

Página 1 - STINGER 2

1 STINGER 2 User’s Operating Manual ______________________________________________________________________ Made i

Página 2

10 the symbol „_―. If there is a difference in both levels balance of the device should be performed through „POWER / CLEAR“. In th

Página 3

11 is done as follows: the „STORE“ button is pressed and held and to the searching coil a definite type of nonferrous metal is approa

Página 4

12 In the „auto discr“ / „reject“ mode the device memorizes only the purity coefficient ID1 of a metal, and in the “AUTO DISCR“ / „

Página 5

13 items or under active stones and highly mineralized soils. In this case, if, for example, an object (stone, ceramics or some iron) has been mem

Página 6

14 be performed in this mode is to press „ON – OFF / CLEAR“ for short, as the searching coil has to be close to the ground surface, at the distance a

Página 7

15 The accumulators' status is shown on the first row on the right as per cents of the capacity (0%-100%). When the capacity decreases below 0

Página 8

16 them is damaged the connection between them is destroyed and practically the device will be left without power supply. 6.2. The working depth is

Página 9

17 service-station (office) of the company manufacturer or the local distributor for change of the storage batteries. The Manufacturer (trad

Página 10

18 any moisture or water from entering the control housing and never allow the cable connector to become submerged in water.  If working in or near

Página 11 -

2 In order to use the device for a maximum long time and without problems, as well as to be able to use all of its options, please read carefully the

Página 12

3 position of the coil to be parallel to the ground surface. Don't over-tighten the plastic bolt and nut to not damage the threading of the bolt

Página 13

4 "DISCR", you have to push the button "VCO / DISCR", at which the device is switched into discrimination mode and the displ

Página 14

5 degree of mineralization of soil. For example, in order to understand how strong is the signal from the soil on a definite location, one ca

Página 15

6 sound. This is done with change in the parameter "Thresh. For this purpose, through the buttons "◄ and ►" desired value can be selec

Página 16

7 shorten the sweeps until you just barely get a response at one spot. The target will be directly below the coil center at this response time – fig.

Página 17

8 After each change of some of these 3 parameters, the device automatically restarts in order the respective settings to be loaded according to the

Página 18

9 Upon localization of foil, aluminium and unstained iron, ID1 and ID2 have their negative values, and both of them have great pos